{"id":5601,"date":"2023-04-13T04:27:55","date_gmt":"2023-04-13T02:27:55","guid":{"rendered":"https:\/\/dev.conel.pl\/?post_type=product&#038;p=5601"},"modified":"2023-04-13T04:27:57","modified_gmt":"2023-04-13T02:27:57","slug":"sterownik-acu","status":"publish","type":"product","link":"https:\/\/conel.pl\/en\/produkty\/produkty-archiwalne\/sterowniki-archiwalne\/sterownik-acu\/","title":{"rendered":"ACU controller"},"content":{"rendered":"<p><strong>Features:<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0room temperature control<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0cascade temperature control<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0supply temperature limitation<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0taking the outside temperature into account in the control<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0control of water and\/or electric heater<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0water or direct evaporation cooler control<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0control of the heat recovery system<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0mixing chamber control<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0thermal protection of fan motors<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0antifreeze protection of the water heater<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0recovery protection against frostbite<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0electric heater protection<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0control of dampers<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0monitoring the condition of filters<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0fan compression control<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0cooperation with external devices<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0calendar function:<\/span>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">weekly clock<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">three time zones in a day<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">blocking of selected functions in a given zone<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Determination of expenditures for drives with an inverter individually for each zone<\/span><\/li>\n<\/ul>\n<\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0service functions<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0function of returning to factory values<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0MODBUS RTU communication protocol - up to two networks<\/span><\/li>\n<\/ul>\n<div align=\"left\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td width=\"67%\">\n<div align=\"left\"><strong class=\"tekst3\">Digital inputs:<\/strong><\/div>\n<\/td>\n<td width=\"33%\">\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">motor protection<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">2 inputs<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">differential pressure switches (filters and fans)<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">2 inputs<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">heater alarm<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">1 input<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">co-. with headquarters<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">1 input<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">remote control<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">1 input<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><strong class=\"tekst3\">Universal inputs:<\/strong><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<ul>\n<li class=\"style9\"><span class=\"tekst3\">for 0-10V signal from the temperature transmitter<\/span><\/li>\n<li class=\"style9\"><span class=\"tekst3\">and\/or measuring the return water temperature from the heater<\/span><\/li>\n<li class=\"style9\"><span class=\"tekst3\">and\/or measuring the temperature of the water return from the cooler<\/span><\/li>\n<li class=\"style9\"><span class=\"tekst3\">and\/or digital input function for ON\/OFF<\/span><\/li>\n<li class=\"style9\"><span class=\"tekst3\">and\/or AUTO\/MANUAL switching<\/span><\/li>\n<li class=\"style9\"><span class=\"tekst3\">and\/or radiator alarm<\/span><\/li>\n<li class=\"style9\"><span class=\"tekst3\">and\/or exchanger pressure switch<\/span><\/li>\n<li class=\"style9\"><span class=\"tekst3\">and\/or filter pressure switch<\/span><\/li>\n<\/ul>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">1 input<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><strong class=\"tekst3\">Measurement inputs:<\/strong><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">PT 1000 temperature sensors<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">4 inputs<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\"><strong>Digital (relay) outputs:<\/strong><\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">fan control<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">2 outputs<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">control of the heating medium pump<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">1 output<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">control of throttle actuators<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">2 outputs<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">working signal for external systems<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">1 output<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">alarm signal for external systems<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">1 output<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">cooling demand signal<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">1 output<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><strong class=\"tekst3\">Analog outputs:<\/strong><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">0-10V signal<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><span class=\"tekst3\">4 (5*) outputs<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><strong class=\"tekst3\">Communication port:<\/strong><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div align=\"left\"><span class=\"tekst3\">RS 485 MODBUS protocol<\/span><\/div>\n<\/td>\n<td>\n<div align=\"left\"><\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"tekst3\" align=\"left\">*The ACU controller can be connected to 5 devices controlled by an analog signal. This is possible because one of the analog outputs - Y2 - can operate 2 devices (heater and cooler). The required condition is that they are not switched on at the same time. The COOL output is used for this, where Y2 is switched between the two terminals of this output for the heating or cooling sequence, respectively.<\/p>","protected":false},"excerpt":{"rendered":"<p class=\"tekst3\" align=\"left\">The ACU controller is a fully functional controller designed for automation systems controlling the operation of supply and exhaust air handling units. It comes in the form of an unencased printed circuit board, which serves as a central unit and a connection strip for peripheral elements. In a clear way, each connector is described with a number, letter and graphic symbol of the element connected to the given terminal. The user thanks to such a solution saves space and time of assembly of the whole control unit, which directly translates into cost reduction.<\/p>","protected":false},"featured_media":3473,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[28,29],"product_tag":[30],"class_list":{"0":"post-5601","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-produkty-archiwalne","7":"product_cat-sterowniki-archiwalne","8":"product_tag-sterowniki-dedykowane-do-wentylacji-i-klimatyzacji","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/conel.pl\/en\/wp-json\/wp\/v2\/product\/5601","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/conel.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/conel.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/conel.pl\/en\/wp-json\/wp\/v2\/media\/3473"}],"wp:attachment":[{"href":"https:\/\/conel.pl\/en\/wp-json\/wp\/v2\/media?parent=5601"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/conel.pl\/en\/wp-json\/wp\/v2\/product_brand?post=5601"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/conel.pl\/en\/wp-json\/wp\/v2\/product_cat?post=5601"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/conel.pl\/en\/wp-json\/wp\/v2\/product_tag?post=5601"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}